Hydrocracking Scale Inhibitor


Description 

This Hydrocracking Scale Inhibitor also know as  anti-fouling agent for hydrocracking unit  is used for preventing scaling at the heat exchanger, reactor, and pipeline of hydrocracking unit in the refinery.


Features

a.It has no components(such as metal and so on)which have bad effects on the activity of hydrogenation catalyst, product distribution, and product properties.

b.Low ash content , lest cause reduced porosity on catalyst bed layer, increased bed pressure drop .

c. The injecting amount is less, but the scale inhibition rate is up to more than 92%.


Technical Index


SolubilityMutually solved with oil
AppearanceBrown liquid
Flashing point (gap), ºC  ≥45
Density (20ºC), kg/m³840-1000
Ash content , % ≤0.1
Freezing point, ºC ≤-12


Using Method

It should be injected from the raw material inlet point, the dosage amount is decided according to the actual condition, the dosage amount is 80-100 ppm for the first month, then it is 60 - 80 ppm normally.

                             

Caution 

a. This Refinery  Scale Inhibitor should be stored in drying , shady and cool storehouses, prevent the interfusion of water and mechanical admixture . 

b. During the process of the application, the customer should choose the best service condition according to the actual case.


INQUIRE
2212501771 [email protected] 13673270471